Systemwilldisplaythecurrentdelaytimeasshownbelow.UsenumerickeystoinputthedesiredARM
delaytime.Enterminutesasa3‐digitnumber0~999andsecondsasa2 ‐digitnumber0~59.Thedefault
valueofARMdelaytimeis30seconds.
Presstoconfirm.Press
toexitwithouteffectinganychange.
5.6.4.19 Alarm Out Time Setting
Asdescribedinalarminputmode, alarmtimeoutdefinesthedurationofalarmoutputbeingpresented
(alarm relay energized), when triggered by the specified alarm input and if the alarm output mode is
configured as “Latched” mode. After the alarm timeout duration, the alarm output will be reset to
normal.The
defaultalarmtimeoutdurationis60seconds.
Notefirealarmhastobemanuallyreset.Itdoesnotlimitedbythealarmtimeoutduration.
5.9.6ALarmEventSetting
Thephysicalalarm inputscan trigger alarm outputs.As described in previous section,thelogicevents,
for example, unknown card, invalid card, expired card, invalid door and etc., can trigger the alarm
outputsaswell.
Pressatthebelowwindowtoconfiguretheeventalarmsetting.
Two submenus are included
in event alarm setting: event alarm time setting and event alarm action
setting,explainedinthefollowingsections.Thescreensofthetwosettingsareshownbelow:
5.6.4.20 Event Alarm Time Setting
Pressat the screen of “Event Alarm Time Setting” to configure event alarm time setting. As
introducedearlier,NAVControllerallowsalogicaleventtotriggeranalarmoutput.Thedurationofthe
alarmoutputcanbespecifiedpereventtype.Differenteventtypescangeneratethedifferentduration
ofthe
alarmoutput.Thedefaultvalueofeventalarmtimeis1minute.
The following windows show the event alarm time setting on different events. All events will be
explainedonebyone.
SYSPINFail
EventAlarm action
Setting
EventAlarm time
Setting
Event Alarm Setting
alarm time
001Min 00Sec
Arm Delay Time
000Min 30Sec