3 StartingUptheController
3.1 Connecting to Power
YoucanpowertheEFC301controllerthroughaspecificPoEnetworkswitchusinganetwork
cable,orbyconnectingtheextensionwireoftheterminalblockontherearpanel.The No.3
andNo.5arethepositivepoleandnegativepoleofthecontroller,respectively.
Figure3‐1
Note:
1. ThevoltagerangeofpowersourceforEFC301controllerisDC11‐16V.Themaximum
currentofthecontrolleris600mA.
2. Thedistancefromthepowersupplytothecontrollershouldbeminimal.Inaddition,
theelectromagneticlockandalarmequipmentmustbepoweredseparatelyfromthe
controller.Poweringthe electromagneticlockandalarmequipmentatthesametimeis
prohibited.
3.2 Restoring the Controller
Torestorethecontrollertothefactorydefaultsettings,pleaseenterthemanagementmenu
of the controller and select “Factory Default Restore” in the management menu of the
system.
3.3 Before First Use
Beforefirstuse,pleasefollowtheinstructionsbelow: