Figure 2-2 First step
4.Inserttheterminaloftheconnectingwireintothesocketofthedevice.
5.Mountthedeviceonthebottomcover.
a.Mounttwoslotspositionedinahorizontaldirectionatthetopoftheinteriorofthe
casingonthecorrespondingplugpinsontheuppercoverofthecontroller.
b.Afterthetwoplugpinsaremounted,thepositionsofotherholesareeasytoalign.
c.Fixtheuppercoverandthebottomcaseofthecontrollerwiththehexagonscrew.
Figure 2-3 Second step
2.2.2 Connecting to the Door Lock / Sensor / Open Button
Eachcontrollerprovidestheinterfaceofthedoorcontrolrelay,correspondingtotheNo.10,
12and14outputextensionwiresonthebackplateofthecontroller.TheNo.12extension
wireisa common terminal(COM),the No.10extension wire is anormally closed terminal
(NC),andtheNo.14extensionwireisanormallyopenedterminal(NO).
2.2.2.1ConnectingtotheElectronicallyControlledLock
The electronic lock mustbe separately powered,and thepower supplyof thelock should
bedeterminedaccordingtotherequirementsoftheelectroniclock.Pleaseselectthecable
oftheelectroniclockcarefullytomeettherequirementsofcurrent.Thetwomajormodels
ofthecommercialelectroniclockareelectronicallycontrolledlockandmagneticlock.The
connectionmethodsofthetwolocksareshownasbelow.