EverFocus ENVR8304E Instrukcja Użytkownika Strona 86

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 177
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 85
ENVR8304D-8CH / ENVR8304E-8CH
77
6.3 Event
You can configure the Alarm, Connection Loss, Motion and Other settings in this menu.
6.3.1 Alarm
Figure 6-23
Alarm: Select an Alarm input number from 1 to 2.
Enable: Check the box to enable the Alarm trigger function for the selected alarm input.
Log: Check the box to record alarm events to log data.
Pre-alarm Record: Check the box to start copying the recordings to the hard disk from 5
seconds before the alarm event occurs. Note that the pre-alarm recording rate will follow the
Normal Speed configured in the earlier section (see 6.1.2 Basic).
Buzzer: Check the box to enable the buzzer when an alarm event is triggered.
Email Notify: Check the box to send email notification with a snapshot file when an alarm
event is detected. Email operation requires valid email entered in the Email setup menu (see
6.6.2 Email).
Network Alarm: Check the box to send out a network alarm to a client PC when an alarm
event occurs. This feature works with EverFocus’ CMS software. You will need to configure
Przeglądanie stron 85
1 2 ... 81 82 83 84 85 86 87 88 89 90 91 ... 176 177

Komentarze do niniejszej Instrukcji

Brak uwag