137
Timeout Mode: Retrigger of Alarms
t
Event
: Duration of alarm input source (motion, contact, system events...)
t
Duration
: Alarm duration for timeout, defined in the event setup menus
t
reaction
: Resulting duration for this alarm mode, related to event record, alarm outputs, OSD
message, buzzer
Timeout+Transparent Mode: Retrigger of Alarms
t
Event
: Duration of alarm input source (motion, contact, system events...)
t
Duration
: Alarm duration for timeout, defined in the event setup menus
t
reaction
: Resulting duration for this alarm mode, related to event record, alarm outputs, OSD
message, buzzer