EverFocus TP-S1016DR Instrukcja Użytkownika Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 10
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
4 of 10 EDR_FW1.6&1.65_release note_en.doc
Inputs / Outputs
SYSTEM ERROR OUTPUT
SPARE_OUT: System error output. TTL-level 5VDC with status "System Okay".
The contact will switch to open state, if one (ore more) of below listed events
appears:
a) HDD full ( if overwrite mode in RECORD
menu is set to STOP)
b) No HDD
c) Overtemperature HDD
d) Power Loss
e) Cooler fan fault
f) Video Loss
g) Record off
Output level:
HIGH (5 V DC): System okay
Open state: System error
PLAYBACK SWITCH INPUT
SPARE_IN: N.O. Control input for playback function, playback with closed contact
In SEARCH menu
The EVENT search supports filter function for start and end time, event type and camera now.
SEARCH MENU
METHOD EVENT
Start DATE 11-09-2005 FR
TIME 00:33:23
END DATE 12-09-2005 FR
TIME 12:27:34
EVENT A/M/V
CAMERA ALL
DISK NO 01
NO SIZE(GB) °C START / END TIME
01 152 42 10-09-2005 07:33:23
14-09-2005 06:53:11
PRESS MENU TO EXIT
PRESS SELECT/MIDDLE TO START SEARCH
4.7 K
1 K
Spare out
Przeglądanie stron 3
1 2 3 4 5 6 7 8 9 10

Komentarze do niniejszej Instrukcji

Brak uwag